zoomHover over image to zoom

GC705W option 0S

DuPont™ ProClean® 3

prod_descrTechnical Data Sheet

DuPont™ ProClean® 3 Procedure Gown, Sterile. Blue. Size 2X Large.

Full Part Number GC705WBU2X00260Sxx  (xx=size)  Help
Fabric DuPont™ ProClean® 3
Design Gown
Seam Welded
Color Blue
Case Count 26 per case
Sizes Universal
Option Codes 0S

FEATURES & PRODUCTS DETAILS -GC705W option 0S

DuPont™ ProClean® 3 Sterile Procedure Gowns are made to the high quality standards you have come to expect from DuPont. Each ProClean® 3 Sterile Procedure Gown is made from spunbond meltblown spunbond (SMS) fabric with anti-static treatment.
  • Ethylene Oxide 10-6 Sterility Assurance Level
  • Meets ANSI/AAMI PB70:2012 Level III Performance Requirements
  • Meets 16 CFR Part 1610 Class 1 Flammability Raiting
  • Individually Packaged
  • Alcohol Repellent
  • Low Lint Generation
  • Set-In Sleeves
  • Generous Cut
  • Extra Long Velcro for Customized Neck Fit
  • Blue
Option Code Description Sizes Part Number
0S Sterile Universal GC705WBU2X00260S

SPECIFICATIONS

  • The procedure gown shall be blue in color.
  • The procedure gown shall be constructed of SMS fabric with anti-static treatment.
  • The procedure gown shall have welded seams.
  • The procedure gown shall be sterile.
  • The procedure gown shall be packaged with one hand towel in overwrap
  • The procedure gown shall have extra long velcro for customized neck fit.
sample_image
Size Sleeve Length Length
Universal 69 124
  • Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
  • This garment only provides partial body coverage. It may be worn in combination with other chemical resistant PPE as required based on the hazard assessment.

FABRIC & CHEMICAL RESISTANCE DATA -GC705W option 0S

Property Test Method Result Std Dev
Basis Weight ASTM D3776 1.4 oz/yd2
Hydrohead AATCC 127 ≥ 50 cm (base fabric)
Impact penetration AATCC 42 <= 1.0 grams (base fabric)
  • Note: for protection from hazardous or infectious liquids, additional barrier tests are required to establish suitability for use.
  • Data presented does not comprise a product specification.

eloqua gating form

  • Warning: Cleanroom apparel should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Cleanroom fabrics should have slip-resistant materials on the outer sole of boots, shoe covers, or other garment surfaces in conditions where slipping could occur.
  • Latex Statement: As of January 1, 2006, DuPont production specifications exclude use of components containing natural rubber latex in the manufacture of Dupont™ Tyvek® IsoClean®, Tyvek™ Micro-Clean® 2-1-2 and ProClean® garments, and DuPont™ ProShield® 10 and DuraTrac™ shoe covers. Notwithstanding, DuPont™ Tyvek® Micro-Clean® 2-1-2 and Duratrac™ shoe covers produced by Cardinal Health prior to May 2008 may contain dry crumb natural rubber latex.