TYVEK

Chemical Protection & Cleanroom Products

Tyvek® Breathability and Durability Demo
Hover over image to zoom

DuPont™ Tyvek® 400

TY454S WH option SR

DuPont™ Tyvek® 400 Boot Cover with Tyvek® FC Skid-Resistant Sole. 18" High. Serged Seams. White.

Full Part Number :

TY454SWHxx0100yy (xx=size;yy=option code)  Help

Fabric / Material :

Tyvek® 400

Design :

Boot Cover

Seam :

Serged

Color :

White

Quantity/Box :

100 per case

Sizes :

LG, XL

Option Codes :

SR

Tyvek® 400 garments are composed of flash spun high density polyethylene which creates a unique, nonwoven material available only from DuPont. Tyvek® 400 provides an ideal balance of protection, durability and comfort of any limited use fabric technology. Tyvek® 400 fabric offers an inherent barrier against particles (down to 1.0 micron in size). Protection is built into the fabric itself; there are no films or laminates to abrade or wear away. Tyvek® 400 fabric's durability advantage over microporous film fabrics delivers consistently better barrier, even after wear and abrasion. Applications include: lead and asbestos abatement/remediation, general maintenance/operations, spray painting, general clean-up.

  • 18" high boot cover with elastic top provides coverage up to calf
  • Sole material composed of Tyvek® 400 FC, a special coating to provide added slip-resistance.
  • One size fits most

AVAILABLE OPTIONS

SPECIFICATIONS

  • The garment shall be constructed of DuPont™ Tyvek® 400-- a patented flash-spun polyethylene fabric.
  • The garment shall be white in color.
  • The garment shall be a boot cover design.
  • The garment shall have serged seams.
  • The garment shall have an elastic ankle and elastic opening.
  • The garment shall have a Tyvek® 400 upper.
  • The garment shall have soles made of Tyvek® FC skid-resistant material..
  • The garment shall be 18™ high.
sample_image

FINISHED DIMENSIONS

Size Boot Length Boot Height
LG 14 18
XL 16 18

ADDITIONAL EQUIPMENT NEEDED

  • Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
  • This garment only provides partial body coverage. It may be worn in combination with other chemical resistant PPE as required based on the hazard assessment.

PHYSICAL PROPERTIES

Data relating to mechanical performance of the fabrics used in DuPont chemical protective clothing, listed for the selected garment according to the test methods and relevant European standard, if applicable. Such properties, including abrasion and flex-cracking resistance, tensile strength and puncture resistance can help in the assessment of protective performance.

Property Test Method Result
Thickness ASTM D1777 5.9 mils
Basis Weight ASTM D3776 1.2 oz/yd2
Burst Strength - Mullen ASTM D774 50 psi
Seam Strength ASTM D1683 > 19 lbf
Breaking Strength - Grab (MD) ASTM D5034 18 lbf/in
Breaking Strength - Grab (CD) ASTM D5034 22 lbf/in
Hydrostatic Head AATCC 127 45 inches H2O
Surface Resistivity (25°C / 55& RH) ASTM D257 < 6.3 x 10^9 ohms/square
Wearing Apparel Flammability 16 CFR 1610 Help Class 1

SPECIAL WARNINGS

  • *Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.
  • *Liquid barrier performance varies based on the amount of liquid that may get on the garment, the length of time the liquid is on the garment, applied pressure and certain physical properties of the liquid. Tyvek®400, Tyvek® 400 D, ProShield®, ProShield® 10, ProShield® 60, Tyvek® 400 FC, and ProShield® 70 garments are not appropriate if during use they are getting wet (liquid is dripping or running, or it is wet to the touch) or if spotting is observed on skin or garments worn under the protective garment. Tyvek® 500 and Tyvek® 600 offer improved liquid barrier, but may not be appropriate if spotting is observed on the skin or garments worn under the protective garment. In applications where a higher liquid barrier is needed, consider Tychem® 2000 and Tychem® 4000 garments with taped seams.
  • Tyvek® 600 and Tyvek® 500 fabric have different fabric physical properties and improved chemical resistance properties than standard Tyvek® 400 garments.
  • **Garments made using Tyvek® 400, Tyvek® 500, Tyvek® 600 and Tyvek® 800J fabrics will burn and possibly melt. None of these garments should be worn near heat, open flames, sparks or any other possible ignition source nor should they be worn in potentially explosive or flammable environments. If these garments do burn or melt while being worn, it may increase the severity of burn injuries even when worn over garments which are flame resistant, including, but not limited to, Nomex® IIIA or Nomex® Comfort garments.
  • *CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this information. It is the user's responsibility to determine the nature and level of hazards and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for information use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher penetration rates than the fabric. Please contact DuPont for specific data. These garments are intended for limited use and should be disposed of after single use. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc are damaged, end user should discontinue use of garment to avoid potential exposure.