C3275T TN
DuPont Tychem® CPF 3
more images
Line Drawing
Taped Seam
|
Tychem® CPF3 fabric is composed of a multi-layer film barrier laminated to a durable 2.0 oz/yd2 polypropylene substrate. Tychem® CPF3 fabric is strong and durable for rigorous activities and rugged situations involving liquid splash and provides barrier to a broad range of chemicals. Typical Applications: chemical handling, petro-chemical, hazardous materials/waste clean-up, fire departments, industrial hazmat teams, utilities, and domestic preparedness. Commonly used in domestic preparedness for situations where the potential to exposure to chemicals exist.
- Knee-length apron/gown design with attached sleeves
- Provides enhanced frontal protection
- Open back for wearer comfort
- Bound seams around neck opening with snap closure
- Ties at waist
- Elastic opening for tighter fit at wrist
See all Product Literature
Product Description
DuPont Tychem® CPF 3 Sleeved Apron. Elastic Wrists. 44" Long. Neck Loop w/ Snaps & Waist Ties. Taped Seams. Tan.
Full Part Number: C3275TTNxx0006yy (xx=size; yy=option code)
| Fabric: | Tychem® CPF 3 |
| Style: | Apron w/ Long Sleeves |
| Seam: | Taped |
| Color: | Tan |
|
Sizes:
|
SM, MD, LG, XL, 2X, 3X, 4X |
| Case Count: | 6 per case |
| Option Codes: | 00 |
Product Terms of Use and Warranty
(PDF)
| Option Code |
Description |
Available Sizes |
Part Number |
| 00 |
Standard |
SM, MD, LG, XL, 2X, 3X, 4X |
C3275TTNxx000600 |
Typical Finished Dimensions
| Size |
Sleeve Length |
Chest Width |
Body Length |
Fits Chest |
Fits Height |
|
SM |
31 |
26 1/2 |
43 |
39 3/4 - 43 1/4 |
5'0" - 5'7" |
|
MD |
31 1/4 |
27 |
43 1/2 |
40 3/4 - 44 1/4 |
5'3" - 5'7" |
|
LG |
31 1/2 |
27 1/2 |
44 1/4 |
41 3/4 - 45 1/4 |
5'5" - 5'9" |
|
XL |
32 1/4 |
28 |
45 |
42 3/4 - 46 1/4 |
5'8" - 6'2" |
|
2X |
33 |
28 1/2 |
45 3/4 |
43 3/4 - 47 1/4 |
6'0" - 6'4" |
|
3X |
33 3/4 |
29 |
46 1/2 |
44 3/4 - 48 1/4 |
6'2" - 6'4" |
|
4X |
34 |
29 1/2 |
47 1/4 |
45 3/4 - 49 1/4 |
6'4" - 6'7" |
- The garment shall be constructed of DuPont™ Tychem® CPF 3 -- a multi-layer composite barrier film laminated to a durable 2.0 oz/yd2 polypropylene substrate.
- The garment shall be tan in color.
- The garment shall be a sleeved apron design.
- The garment shall have taped seams.
- The tape used to cover the seams shall be a film composite with equal to or greater chemical resistance than the base fabric.
- The garment shall have a neck loop with snaps.
- The garment shall have waist ties.
- The garment shall have elastic wrists.
- The garment shall be 44" in length.
- Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
- This garment only provides partial body coverage. It may be worn in combination with other chemical resistant PPE as required based on the hazard assessment.
- Please read, understand and follow the Tychem® User Manual.
Tychem® CPF 3 - Fabric Data
| Property |
Test Method |
Result |
| Thickness |
ASTM D1117 |
18 mils |
| Basis Weight |
ASTM D751 |
4.4 oz/yd2 |
| Tear Resistance - Trap Tear (MD) |
ASTM D5597 |
21 lbf |
| Tear Resistance - Trap Tear (CD) |
ASTM D5597 |
30 lbf |
| Breaking Strength - Grab (MD) |
ASTM D751 |
62 lbf |
| Breaking Strength - Grab (CD) |
ASTM D751 |
59 lbf |
| Puncture, Propagation, Tear Resistance (MD) |
ASTM D5034 |
not available |
| Puncture, Propagation, Tear Resistance (CD) |
ASTM D5034 |
not available |
| Wearing Apparel Flammability |
16 CFR 1610 |
Class 1 |
*Typical values, not specifications.
Testing Details
Tychem® CPF 3 - Fabric Data
| Hazard / Chemical Name |
CAS Number |
Phase |
Breakthrough Time
(average, normalized to 0.1 ug/cm2/min)
/ Performance
|
| 1,1,2,2-Tetrachloroethylene |
127-18-4 |
Liquid |
>480 |
| 1,1,2-Trichloro-1,2,2-trifluoroethane |
76-13-1 |
Vapor |
>480 |
| 1,3-Butadiene (gas) |
106-99-0 |
Vapor |
>480 |
| 1-Aminobutane |
109-73-9 |
Liquid |
>480 |
| 1-Bromopropane |
106-94-5 |
Liquid |
>480 |
| 1-Propyl bromide |
106-94-5 |
Liquid |
>480 |
| Acetic acid |
64-19-7 |
Liquid |
84 |
| Acetic anhydride |
108-24-7 |
Liquid |
>480 |
| Acetone |
67-64-1 |
Liquid |
>480 |
| Acetonitrile |
75-05-8 |
Liquid |
imm. |
| Acetyl chloride |
75-36-5 |
Liquid |
>480 |
| Acrolein |
107-02-8 |
Liquid |
178 |
| Acrylonitrile |
107-13-1 |
Liquid |
13 |
| Adiponitrile |
111-69-3 |
Liquid |
>480 |
| Allyl alcohol |
107-18-6 |
Liquid |
>480 |
| Allyl chloride |
107-05-1 |
Liquid |
12 |
| Aminobutane, 1- |
109-73-9 |
Liquid |
>480 |
| Ammonia (gas) |
7664-41-7 |
Vapor |
12 |
| Ammonia (liquid, < -35°C) |
7664-41-7 |
Liquid |
>480 |
| Ammonium chloride (sat. sol. in water) |
12125-02-9 |
Liquid |
>480 |
| Ammonium hydroxide (28%-30%) |
1336-21-6 |
Liquid |
89 |
| Amyl acetate, n- |
628-63-7 |
Liquid |
>480 |
| Anhydrous ammonia (gas) |
7664-41-7 |
Vapor |
12 |
| Anhydrous ammonia (liquid, < -35°C) |
7664-41-7 |
Liquid |
>480 |
| Aniline |
62-53-3 |
Liquid |
320 |
| Anthracene (sat. sol. in toluene) |
120-12-7 |
Liquid |
>480 |
| Asbestos (all forms) |
1332-21-4 |
Solid |
May be Suitable for Use |
| Benzene |
71-43-2 |
Liquid |
>480 |
| Benzene sulfonyl chloride |
98-09-9 |
Liquid |
>480 |
| Benzonitrile |
100-47-0 |
Liquid |
450 |
| Benzotrichloride |
98-07-7 |
Liquid |
>480 |
| Benzoyl chloride |
98-88-4 |
Liquid |
>480 |
| Benzyl chloride |
100-44-7 |
Liquid |
>480 |
| Benzyl chloroformate |
501-53-1 |
Liquid |
>480 |
| Benzyl cyanide |
140-29-4 |
Liquid |
>390 |
| Beryllium |
7440-41-7 |
Solid |
May be Suitable for Use |
| Biological fluids w/ potentially infectious diseases |
unknown |
Liquid |
May be Suitable for Use |
| Blood |
unknown |
Liquid |
May be Suitable for Use |
| Blood w/ potentially infectious diseases |
unknown |
Liquid |
May be Suitable for Use |
| Bodily fluids |
unknown |
Liquid |
May be Suitable for Use |
| Bodily fluids w/ potentially infectious diseases |
unknown |
Liquid |
May be Suitable for Use |
| Boron trifluoride dimethyletherate |
353-42-4 |
Liquid |
>480 |
| Bromine |
7726-95-6 |
Liquid |
imm. |
| Bromofluorobenzene, 4- |
460-00-4 |
Liquid |
>480 |
| Bromopropane, 1- |
106-94-5 |
Liquid |
>480 |
| Butadiene, 1,3- (gas) |
106-99-0 |
Vapor |
>480 |
| Butan-1-amine |
109-73-9 |
Liquid |
>480 |
| Butanol, n- |
71-36-3 |
Liquid |
>480 |
| Butyl ether, n- |
142-96-1 |
Liquid |
>480 |
| Butylamine, n- |
109-73-9 |
Liquid |
>480 |
| Carbon disulfide |
75-15-0 |
Liquid |
16 |
| Carbon tetrachloride |
56-23-5 |
Liquid |
>480 |
| Caustic potash (45%) |
1310-58-3 |
Liquid |
>480 |
| Caustic soda (42-50%) |
1310-73-2 |
Liquid |
>480 |
| Chlordane (44%) |
57-74-9 |
Liquid |
>480 |
| Chlorine (gas) |
7782-50-5 |
Vapor |
>480 |
| Chlorine (liquid, -70° C) |
7782-50-5 |
Liquid |
>480 |
| Chlorine sulfide (80%) |
10545-99-0 |
Liquid |
imm. |
| Chloro-benzotrifluoride, 4- |
98-56-6 |
Liquid |
460 |
| Chloroacetic acid (70%-80%) |
79-11-8 |
Liquid |
>480 |
| Chloroacetone |
78-95-5 |
Liquid |
>480 |
| Chloroacetyl chloride |
79-04-9 |
Liquid |
77 |
| Chlorobenzene |
108-90-7 |
Liquid |
63 |
| Chlorobenzotrichloride, 4- |
5216-25-1 |
Liquid |
>480 |
| Chloroethanol, 2- |
107-07-3 |
Liquid |
>480 |
| Chloroform |
67-66-3 |
Liquid |
imm. |
| Chlorosulfonic acid |
7790-94-5 |
Liquid |
330 |
| Citric acid (50% in water) |
77-92-9 |
Liquid |
>480 |
| Cresol, o- |
95-48-7 |
Liquid |
330 |
| Cumene |
98-82-8 |
Liquid |
364 |
| Cyclohexane |
110-82-7 |
Liquid |
>480 |
| Cyclooctadiene |
1552-12-1 |
Liquid |
>480 |
| Dibromo-3-chloropropane, 1,2- |
96-12-8 |
Liquid |
>480 |
| Dichloroethyl ether |
111-44-4 |
Liquid |
>480 |
| Dichloromethane |
75-09-2 |
Liquid |
imm. |
| Dichloropropene, 1,3- |
542-75-6 |
Liquid |
imm. |
| Diesel fuel |
68334-30-5 |
Liquid |
199 |
| Diethanolamine |
111-42-2 |
Liquid |
>480 |
| Diethyl sulfate |
64-67-5 |
Liquid |
>480 |
| Diethylamine |
109-89-7 |
Liquid |
>480 |
| Diethylenetriamine |
111-40-0 |
Liquid |
>480 |
| Dimethyl sulfate |
77-78-1 |
Liquid |
>480 |
| Dimethyl sulfoxide |
67-68-5 |
Liquid |
>480 |
| Dimethyl-acetamide, N,N- |
127-19-5 |
Liquid |
>480 |
| Dimethylamine |
124-40-3 |
Vapor |
>480 |
| Dimethylaniline, N,N- |
121-69-7 |
Liquid |
imm. |
| Dimethylene oxide (gas) |
75-21-8 |
Vapor |
>480 |
| Dimethylene oxide (liquid, 11° C) |
75-21-8 |
Liquid |
18 |
| Dimethylformamide, N,N- |
68-12-2 |
Liquid |
>480 |
| Dimethylmaleate |
624-48-6 |
Liquid |
>480 |
| Dioxane, 1,4- |
123-91-1 |
Liquid |
>480 |
| Dirt (general) |
unknown |
Solid |
May be Suitable for Use |
| Disodium sulfide (60% w/w in water slurry) |
1313-82-2 |
Liquid |
>480 |
| Disulfur dichloride |
10025-67-9 |
Liquid |
210 |
| Dytek® A |
15520-10-2 |
Liquid |
>480 |
| Epichlorohydrin |
106-89-8 |
Liquid |
67 |
| Epoxyethane (gas) |
75-21-8 |
Vapor |
>480 |
| Epoxyethane (liquid, 11° C) |
75-21-8 |
Liquid |
18 |
| Ethanol |
64-17-5 |
Liquid |
>480 |
| Ethanolamine |
141-43-5 |
Liquid |
>480 |
| Ethyl Cellosolve® |
110-80-5 |
Liquid |
306 |
| Ethyl acetate |
141-78-6 |
Liquid |
>480 |
| Ethyl alcohol |
64-17-5 |
Liquid |
>480 |
| Ethyl ether |
60-29-7 |
Liquid |
>480 |
| Ethyl hydroxide |
64-17-5 |
Liquid |
>480 |
| Ethylene dibromide |
106-93-4 |
Liquid |
>480 |
| Ethylene dichloride |
107-06-2 |
Liquid |
>480 |
| Ethylene glycol acrylate |
818-61-1 |
Liquid |
>480 |
| Ethylene oxide (gas) |
75-21-8 |
Vapor |
>480 |
| Ethylene oxide (liquid, 11° C) |
75-21-8 |
Liquid |
18 |
| Feces (solid) |
unknown |
Solid |
May be Suitable for Use |
| Fertilizer (general; solid form) |
unknown |
Solid |
May be Suitable for Use |
| Fiberglass |
unknown |
Solid |
May be Suitable for Use |
| Fluorobenzene |
462-06-6 |
Liquid |
>480 |
| Fluoroboric acid (48-50%) |
16872-11-0 |
Liquid |
>480 |
| Fluorosilicic acid |
16961-83-4 |
Liquid |
>480 |
| Formalin |
mixture |
Liquid |
>480 |
| Formic acid |
64-18-6 |
Liquid |
>480 |
| Fungicide (general; solid form) |
unknown |
Solid |
May be Suitable for Use |
| Furfural |
98-01-1 |
Liquid |
>480 |
| Gasoline |
86290-81-5 |
Liquid |
>480 |
| HCN (Hydrogen cyanide) (gas) |
74-90-8 |
Vapor |
30 |
| Hazardous Particles (larger than 0.3 micron in size) |
unknown |
Solid |
May be Suitable for Use |
| Hazardous Particles (larger than 1 micron in size) |
unknown |
Solid |
May be Suitable for Use |
| Heptane |
142-82-5 |
Liquid |
>480 |
| Herbicide (general; solid form) |
unknown |
Solid |
May be Suitable for Use |
| Hexamethylenediamine, 1,6- (50° C) |
124-09-4 |
Liquid |
45 |
| Hexane, n- |
110-54-3 |
Liquid |
>480 |
| Hexone |
108-10-1 |
Liquid |
>480 |
| Hydriodic acid (55-57%) |
10034-85-2 |
Liquid |
>480 |
| Hydrobromic acid (48-49%) |
10035-10-6 |
Liquid |
>480 |
| Hydrochloric acid (37%) |
7647-01-0 |
Liquid |
>480 |
| Hydrocyanic acid (gas) |
74-90-8 |
Vapor |
30 |
| Hydrofluoric acid (48-51%) |
7664-39-3 |
Liquid |
180 |
| Hydrogen chloride (gas) |
7647-01-0 |
Vapor |
>480 |
| Hydrogen cyanide (gas) |
74-90-8 |
Vapor |
30 |
| Hydrogen fluoride (gas) |
7664-39-3 |
Vapor |
170 |
| Hydrogen fluoride (liquid, 0° C) |
7664-39-3 |
Liquid |
50 |
| Hydrogen peroxide (50%) |
7722-84-1 |
Liquid |
>480 |
| Hydrogen sulfide |
7783-06-4 |
Vapor |
imm. |
| Hypophosphorus acid (50%) |
6303-21-5 |
Liquid |
>480 |
| IPA (Isopropyl alcohol) |
67-63-0 |
Liquid |
>480 |
| Insecticide (general; solid form) |
unknown |
Solid |
May be Suitable for Use |
| Isopropanol |
67-63-0 |
Liquid |
>480 |
| Isopropyl alcohol |
67-63-0 |
Liquid |
>480 |
| Isopropylamine |
75-31-0 |
Liquid |
15 |
| Jet A fuel |
8008-20-6 |
Liquid |
>480 |
| KOH (Potassium hydroxide) (45%) |
1310-58-3 |
Liquid |
>480 |
| Kerosene |
8008-20-6 |
Liquid |
>480 |
| Lead |
7439-92-1 |
Solid |
May be Suitable for Use |
| Lewisite (10 g/m²) |
541-25-3 |
Liquid |
120 |
| Lime |
mixture |
Solid |
May be Suitable for Use |
| Lye (42-50%) |
1310-73-2 |
Liquid |
>480 |
| MEK (Methyl ethyl ketone) |
78-93-3 |
Liquid |
>480 |
| MIBK (Methyl isobutyl ketone) |
108-10-1 |
Liquid |
>480 |
| Mercury |
7439-97-6 |
Liquid |
>480 |
| Mesityl oxide |
141-79-7 |
Liquid |
>480 |
| Methanol |
67-56-1 |
Liquid |
imm. |
| Methyl chloride (gas) |
74-87-3 |
Vapor |
>480 |
| Methyl ethyl ketone |
78-93-3 |
Liquid |
>480 |
| Methyl isobutyl ketone |
108-10-1 |
Liquid |
>480 |
| Methyl isocyanate |
624-83-9 |
Liquid |
12 |
| Methyl mercaptan |
74-93-1 |
Vapor |
>480 |
| Methyl tert-butyl ether |
1634-04-4 |
Liquid |
>480 |
| Methylamine (40% in water) |
74-89-5 |
Liquid |
140 |
| Methylene bromide |
74-95-3 |
Liquid |
40 |
| Methylene chloride |
75-09-2 |
Liquid |
imm. |
| Methylformamide, N- |
123-39-7 |
Liquid |
>480 |
| Mold spores |
unknown |
Solid |
May be Suitable for Use |
| Muriatic acid (37%) |
7647-01-0 |
Liquid |
>480 |
| N,N-Dimethylformamide |
68-12-2 |
Liquid |
>480 |
| NaOH (Sodium hydroxide) (42-50%) |
1310-73-2 |
Liquid |
>480 |
| Naphthalene |
91-20-3 |
Liquid |
>480 |
| Nicotine |
54-11-5 |
Liquid |
>480 |
| Nitric acid (90%) |
7697-37-2 |
Liquid |
>480 |
| Nitric acid, red fuming |
52583-42-3 |
Liquid |
>480 |
| Nitrobenzene |
98-95-3 |
Liquid |
>480 |
| Nitropropane, 2- |
79-46-9 |
Liquid |
>480 |
| Non-Hazardous Particles (larger than 0.3 micron in size) |
unknown |
Solid |
May be Suitable for Use |
| Non-Hazardous Particles (larger than 1 micron in size) |
unknown |
Solid |
May be Suitable for Use |
| Oleum (65% free SO3) |
8014-95-7 |
Liquid |
15 |
| Oxalic acid (sat. sol. in water) |
144-62-7 |
Liquid |
>480 |
| PCB (50% in trichlorobenzene) |
mixture |
Liquid |
>480 |
| Pentanal, n- |
71-41-0 |
Liquid |
>480 |
| Pesticide (general; solid form) |
unknown |
Solid |
May be Suitable for Use |
| Phenethyl alcohol, 2- |
60-12-8 |
Liquid |
>480 |
| Phenol (85-90%) |
108-95-2 |
Liquid |
85 |
| Phenylethanol, 1- |
98-85-1 |
Liquid |
>480 |
| Phosgene |
75-44-5 |
Vapor |
>480 |
| Phosphoric acid (75%) |
7664-38-2 |
Liquid |
15 |
| Phosphorus oxychloride |
10025-87-3 |
Liquid |
410 |
| Phosphorus trichloride |
7719-12-2 |
Liquid |
>480 |
| Picoline, 2- |
109-06-8 |
Liquid |
>480 |
| Polychlorinated biphenyl (50% in trichlorobenzene) |
mixture |
Liquid |
>480 |
| Potash lye (45%) |
1310-58-3 |
Liquid |
>480 |
| Potassium carbonate |
584-08-7 |
Liquid |
>480 |
| Potassium hydroxide (45%) |
1310-58-3 |
Liquid |
>480 |
| Propyl bromide, 1- |
106-94-5 |
Liquid |
>480 |
| Propylamine, n- |
107-10-8 |
Liquid |
100 |
| Propylbromide, n- |
106-94-5 |
Liquid |
>480 |
| Propylene oxide, 1,2- |
75-56-9 |
Liquid |
30 |
| Pyridine |
110-86-1 |
Liquid |
>480 |
| Radioactive particles |
unknown |
Solid |
May be Suitable for Use |
| Sarin (10 g/m²) |
107-44-8 |
Liquid |
120 |
| Silicon tetrachloride |
10026-04-7 |
Liquid |
>480 |
| Sodium disulfite (38% w/w in water) |
7681-57-4 |
Liquid |
23 |
| Sodium hydroxide (42-50%) |
1310-73-2 |
Liquid |
>480 |
| Sodium hypochlorite (13%) |
7681-52-9 |
Liquid |
>480 |
| Sodium hypochlorite (30%) |
7681-52-9 |
Liquid |
>480 |
| Sodium metabisulfite (38% w/w in water) |
7681-57-4 |
Liquid |
23 |
| Sodium pyrosulfite (38% w/w in water) |
7681-57-4 |
Liquid |
23 |
| Sodium sulfide (60% w/w in water slurry) |
1313-82-2 |
Liquid |
>480 |
| Soman (10 g/m²) |
96-64-0 |
Liquid |
>480 |
| Styrene |
100-42-5 |
Liquid |
>480 |
| Sulfonyl chloride |
7791-25-5 |
Liquid |
120 |
| Sulfur chloride |
10025-67-9 |
Liquid |
210 |
| Sulfur dichloride (80%) |
10545-99-0 |
Liquid |
imm. |
| Sulfur monochloride |
10025-67-9 |
Liquid |
210 |
| Sulfur mustard (10 g/m²) |
505-60-2 |
Liquid |
120 |
| Sulfur trioxide |
7446-11-9 |
Liquid |
imm. |
| Sulfuric acid |
7664-93-9 |
Liquid |
>480 |
| Tar balls |
unknown |
Solid |
May be Suitable for Use |
| Tetrachloroethylene, 1,1,2,2- |
127-18-4 |
Liquid |
>480 |
| Tetraethyl lead |
78-00-2 |
Liquid |
>480 |
| Tetrahydrofuran |
109-99-9 |
Liquid |
>480 |
| Thioglycolic acid |
68-11-1 |
Liquid |
>480 |
| Thionyl chloride |
7719-09-7 |
Liquid |
15 |
| Titanium tetrachloride |
7550-45-0 |
Liquid |
120 |
| Toluene |
108-88-3 |
Liquid |
>480 |
| Toluene-2,4-diisocyanate (80%) |
584-84-9 |
Liquid |
>480 |
| Trichloro-1,2,2-trifluoroethane, 1,1,2- |
76-13-1 |
Vapor |
>480 |
| Trichlorobenzene, 1,2,4- |
120-82-1 |
Liquid |
>480 |
| Trichloroethane, 1,1,1- |
71-55-6 |
Liquid |
>480 |
| Trichloroethanol, 2,2,2- |
115-20-8 |
Liquid |
>480 |
| Trichloroethylene |
79-01-6 |
Liquid |
>480 |
| VX Nerve agent (10 g/m²) |
50782-69-9 |
Liquid |
>480 |
| Vinyl chloride |
75-01-4 |
Vapor |
>480 |
| Vinylidene chloride |
75-35-4 |
Liquid |
170 |
| Xylene, o- |
95-47-6 |
Liquid |
>480 |
| d-Limonene |
5989-27-5 |
Liquid |
>480 |
| n-Hexane |
110-54-3 |
Liquid |
>480 |
| n-Propylbromide |
106-94-5 |
Liquid |
>480 |
- *CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use.
Cellosolve® and Selexol are registered trademarks of Dow Chemcals Company. Skydrol® is a registered trademark of Solutia.
|
|
Tychem® CPF 3
Hood Extends Over Chest Hook & Loop Waist Closure Taped Seams
Part number: C3651TTNxx000600
|
|
|
|
|
Cool-Guard® Vest
Cooling Vest w/ Packets
Part number: 996000BU00000100
|
|
|
|
|
Cool-Guard® Spare Packets
Set of Four (4)
Part number: 9960300000000100
|
|
|
- Are Tychem® CPF 3 garments flame resistant or flame retardant (FR)?
- Are Tychem® CPF 3 garments anti-static or static dissipative?
- What is the ambient working temperature range for Tychem® CPF 3 garments?
- How should Tychem® CPF 3 garments be stored?
- Is it possible to wash and re-use Tychem® CPF 3 garments?
- What determines if the garment is contaminated?
- What is the shelf life of Tychem® CPF 3 garments?
- In what ways can I dispose of Tychem® CPF 3 garments?
- In what ways can I manage or prevent heat stress?
- Where can I find a MSDS (Material Safety Data Sheet) for Tychem® CPF 3 garments?
- Are Tychem® CPF 3 garments latex free?
- 1.Are Tychem® CPF 3 garments flame resistant or flame retardant (FR)?
- Other than Tychem® ThermoPro, Tychem® chemical protective garments will ignite and continue to burn.
Wearing garments made of Nomex® or any other flame-resistant fabric under Tychem® garments, other than Tychem® ThermoPro, will not reduce burn injury during a fire or electric arc exposure. Other than Tychem® ThermoPro, Tychem® garments will burn and possibly melt when exposed to a fire or electric arc flash; this may increase burn injuries even when worn over garments made of Nomex® or any other flame-resistant fabric.
And because Tychem® garments melt, except for Tychem® ThermoPro, do not wear Tychem® garments under a garment made of Nomex® or any other flame resistant fabric if the potential for fire or electric arc flash exists.
Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits when wearing a Tychem® garment, including when wearing a Tychem® ThermoPro garment. Retreat immediately if you encounter such an environment while wearing any Tychem® garment, including Tychem® ThermoPro.
No Tychem® garment, including Tychem® ThermoPro, is intended for fire fighting activities, nor for protection from hot liquids, steam, molten metals, welding, or thermal radiation. Tychem® ThermoPro garments are designed and tested to help reduce injury during escape from a fire and to provide some protection from electric arcs.
top
- 2.Are Tychem® CPF 3 garments anti-static or static dissipative?
- The fabric used to make Tychem® CPF 3 garments has not received any special treatment to improve static dissipative properties.
In situations where static dissipation level is a critical performance property, end-users should evaluate the performance of their entire ensemble as worn including outer garments, inner garments, footwear and other PPE. In order for any garment system to be static dissipative, it must be able to drain a charge buildup through proper grounding devices, such as, but not limited to, workstation grounding clips or static-dissipative floors.
Under certain conditions, such as cold and dry weather, it is possible that garments might build and discharge static electricity. Discharges are not normally dangerous except in situations where the generation of an electrical spark could ignite a flammable atmosphere or startle the wearer. When operating around flammable chemicals, take steps to eliminate potential static discharges. In these situations, suggested steps include, but not limited to, water spray, the use of an overcover, raising humidity level of the work area, use of a commercial, anti-static application coating, grounding straps on equipment and personnel, inherently static-dissipating under- and over-garments, and testing of the worker's static dissipation before entry into the classified area.
However, in the case of explosive or flammable atmospheres, even if steps are taken to manage static formation and dissipate static charge, the risk of severe injury remains if an uncontrolled or accidental ignition occurs. Do not wearTychem® CPF 3 chemical protective garments in potentially flammable or explosive atmospheres. Do not knowingly enter an environment in which the concentration of flammable gas is within flammable or explosive limits while wearing a Tychem® CPF 3 garment. If you determine that you are in a potentially flammable or explosive environment, retreat immediately.
top
- 3.What is the ambient working temperature range for Tychem® CPF 3 garments?
- Tychem® garments can be worn in ambient temperatures of -13°F (-25°C) to 120°F (49°C).
In colder environments, Tychem® garments can become stiff. If cold enough, the fabric may even become brittle. Please be aware that the heat stress of the wearer becomes a greater concern in higher ambient temperatures. At higher temperatures, chemical hazards can become more aggressive. Breakthrough times and permeation rates may change at higher temperatures. The published permeation data per ASTM F739 is performed at ambient temperatures (approximately 72-81° F ; 22-27° C).
Caution: Tychem® fabrics offer little or no thermal insulation to protect the wearer's skin from prolonged exposure to hot or cold.
top
- 4.How should Tychem® CPF 3 garments be stored?
- Store Tychem® CPF 3 garments in a cool, dark, dry location free of dirt and insects. Sunlight, ozone, high temperatures (>120° F ; 49° C), vehicle exhaust fumes, compression under heavy weights and sharp edges or projections are some conditions known to degrade the materials in these garments.
Store Tychem® CPF 3 garments in boxes, in bags or on hangers. Never step on protective garments. Never place or store heavy objects on top of protective garments.
top
- 5.Is it possible to wash and re-use Tychem® CPF 3 garments?
- DuPont does not recommend washing contaminated Tychem® CPF 3 garments for re-use. These garments are designed for limited-use. They can be worn until damaged, altered or contaminated. However, if the garments have not been contaminated, they can be cleaned for hygienic purposes and re-used. Please refer to the section on Decontamination and Cleaning on page 12 in the Tychem® User Manual for more information.
top
- 6.What determines if the garment is contaminated?
- The decision on whether or not a garment has been contaminated is made by local managers responsible for PPE based on an analysis of the incident in which the garment was used. This analysis may include exposure time, chemicals involved, level of exposure, proximity to the actual release, tasks performed, and environmental monitoring in the area in which the garment was worn.
Garments that are damaged, altered, or show signs of contamination, such as discoloration, odor, stiffening or cracks, should not be used.
top
- 7.What is the shelf life of Tychem® CPF 3 garments?
- Tychem® garments may be used for at least 5 years after receipt by the end user as long as all of the following conditions are met:
- The garment has been stored properly (view storage conditions)
- The garment has not been damaged, altered or contaminated
- The garment passes a full visual inspection (view garment inspection instructions)
- In the case of Level A garments, pass the ASTM F1052 inflation test. (NOTE: Level A suits must be tested upon receipt and annually. The results of these tests must be documented on the record provided with each garment. Additionally, the diaphragm in each exhaust valve must be replaced every two years. See the DuPont Tychem® User Manual and the DuPont Protection Technologies Instruction Manual for Universal Pressure Test Kit for more information.)
After 5 years, if all of the above conditions are met, it is at the sole discretion of the end user whether or not to continue using the garment. It is suggested that garments be labeled and retired to "Training Use Only" after 5 years from receipt by the end user.
top
- 8.In what ways can I dispose of Tychem® CPF 3 garments?
- If not contaminated, Tychem® CPF 3 garments may be landfilled or incinerated in accordance with local regulations. Uncontaminated chemical protective garments may be incinerated in a facility that is capable of handling mixtures containing plastics. Likewise, an uncontaminated chemical protective garment may be buried in a facility that accepts plastic materials. Tychem® CPF 3 garments may contain several different materials; they are not suitable for recycling.
Contaminated garments that cannot be handled safely without protective equipment must be disposed of with other hazardous wastes, either through incineration or landfill per local regulations.
Before discarding, cut off a sleeve or a leg so the garments cannot be worn again as protective clothing.
top
- 9.In what ways can I manage or prevent heat stress?
- Chemical protective clothing can interfere with the natural regulation of body temperature. This can lead to a rise in core body temperature and heat stress. Implementing a conservative work/rest schedule or using a cooling system like the DuPont Cool-Guard® vest may be effective in reducing heat stress. (Note: Do not wear cooling vests in potentially flammable or explosive environments.)
Be aware of the symptoms and treatment of heat stress. If you or your co-workers have symptoms of heat stress such as nausea, dizziness, high heart rates, or excessive heat build-up, leave the work area immediately and remove the ensemble as quickly as possible after decontamination and seek professional care.
The maximum length of time the chemical protective clothing can be worn depends on variables such as the air supply, ambient conditions, climate inside the ensemble, physical and psychological conditions of the wearer, work rate and work load. The TLV® pocket guide from the American Conference of Governmental Industrial Hygienists (ACGIH, Cincinnati) provides corrected heat stress limits for some garments. Similar information is available on the federal OSHA web site (www.OSHA.gov). The WBGT correction factor for chemical protective garments is at least 10°C or higher for chemical garments made of impervious films (such as Tychem® garments) and covering the entire body (hooded coverall or encapsulating designs). For Tyvek® coveralls, the WBGT correction factor is 2°C with a hood and 1°C without a hood.
top
- 10.Where can I find a MSDS (Material Safety Data Sheet) for Tychem® CPF 3 garments?
- Material Safety Data Sheets (MSDS) are written in accordance with applicable federal regulations, 29 CFR 1910.1200, to communicate health and safety data on usage and handling of hazardous chemicals. Under this regulation, DuPont Tyvek®, Tyvek® Dual, Tyvek® FC, ProShield®, ProShield® 3, ProShield® ProShield® Basic, NexGen®, Tempro® and Tychem® materials and garments are defined as articles, not chemicals, and the MSDS and labeling requirments in that standard do not apply.
top
- 11.Are Tychem® CPF 3 garments latex free?
- As of January 1, 2006, all DuPont Tychem® garments that are manufactured by DuPont and sold in the United States are manufactured under specifications that exclude components containing natural rubber latex or are manufactured in such a way that any natural rubber latex will not come in contact with the wearer during normal handling and use. However, anyone who begins to exhibit allergic response during the use of DuPont products should immediately cease using these products. The incident should also be reported to DuPont at 1-800-441-3637 so that an investigation can be initiated.
top
|
|